Automated FTIR solution wins Best New Analytical Instrument Award

Fuel analysis

Automated FTIR solution wins Best New Analytical Instrument Award

26 Nov, 2026

Anton Paar’s Lyza 7000 FTIR solution has received the 2026 Best New Analytical Instrument Award at the Gulf Coast Conference (GCC) New Product Showcase in Galveston, Texas. The award recognises the solution’s innovative approach to routine liquid FTIR analysis, combining the Lyza 7000 FTIR spectrometer, the Flow Cell Module V-ATR ZnSe and the Xsample 5200 sample changer to enable fully automated determination of fatty acid methyl esters (FAME) in diesel.

FAME content is a key control parameter in diesel blending, incoming goods inspection, terminal operations and product release. The Lyza 7000 FAME workflow combines a vertical 12-bounce ZnSe ATR crystal for efficient flow-through operation with pre-installed evaluation models for fast, reliable results.

Configured for ASTM D7371, the system delivers quantified FAME results directly on the Lyza 7000 touchscreen. Pre-installed chemometric models cover the full FAME concentration range from 0 per cent to 100 per cent. For the key range of 0 per cent to 20 per cent, users do not need to prepare their own calibration standards for initial calibration, enabling laboratories to start routine testing straight out of the box. With Xsample 5200, filling, measurement, cleaning and drying are automated for sequences of up to 32 samples, enabling consistent, unattended analysis with minimal operator involvement.

“At GCC, the automation of FTIR analysis was a major talking point in many of my conversations,” says Daniel Vetter, Global Product Manager for FTIR Spectroscopy at Anton Paar. “The ability to load a batch of diesel samples and let the system handle the entire analysis really caught people’s attention. Our new solution frees up laboratory staff to focus on other tasks instead of spending their time handling samples.”

For laboratories with lower sample throughput, Flow Cell Module V-ATR ZnSe also supports manual filling with a syringe or automated single-sample handling with Xsample 3200. Additional transmission flow cell modules enable FAME analysis according to ASTM D7806 and DIN EN 14078, giving laboratories the flexibility to choose the configuration that best matches their testing requirements.

The GCC award underscores the potential of combining innovative ATR technology with fully automated sample handling. With direct FAME results, ready-to-use methods and unattended operation, Anton Paar brings a new level of automation to routine diesel quality control.

Latest News

PIN 27.5 Oct/Nov 26

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
Innovate UK awards £9.3m for automated medicines manufacturing labs
Explore more Arrow
Envirotech Online
US mercury inventory shows falling supply but rising use in manufacturing processes
Explore more Arrow
Pollution Solutions Online
Pump and mixer service at paper mill set to reach 40 years
Explore more Arrow
Chromatography Today
Thermo-analytical GC-MS standard for microplastics in drinking water reaches final draft stage
Explore more Arrow