Gas detector
A fixed gas detector mounted in a hard-to-reach spot can turn a routine performance check into a cumbersome job. KIN-TEK Analytical, Inc.’s portable Span Chek™ 2400 (SC2400) generates calibration gas at the point of use, giving maintenance and instrumentation teams an alternative to carrying gas canisters between test locations.
Designed for chemical plants, gas processing facilities and other industrial sites, the SC2400 supports performance verification and bump testing of fixed, portable and personal gas monitors. The self-contained unit uses Trace Source™ permeation tubes and an internal pump that draws in filtered ambient air to dilute the gas released by the tubes. By adjusting the dilution flow, technicians can check a detector’s response at several concentrations using the same permeation tube.
The system accommodates up to four compatible permeation tubes operating at the same temperature, allowing users to generate single-gas or multicomponent mixtures. The SC2400 can generate calibration gas for detector checks involving hydrogen sulphide, sulphur dioxide, ammonia and volatile organic compounds such as benzene and toluene.
Housed in a lightweight, weather-resistant carrying case, the SC2400 can operate for up to eight hours on its rechargeable battery. The temperature-controlled oven supports setpoints from 5°C above ambient to 60°C on battery power and up to 100°C when connected to the charger.
The application note, Simplifying Gas Monitor Performance Verification Protocols Using a Portable Permeation System, covers system setup, test gas selection and how flow adjustments change the concentration delivered to the detector.
For a copy of the application note or to discuss a specific gas monitoring application, email or visit KIN-TEK Analytical.
PIN 27.5 Oct/Nov 26