• New High Resolution Continuum Source Atomic Absorption Spectrometer Launched

Analytical Instrumentation

New High Resolution Continuum Source Atomic Absorption Spectrometer Launched

Aug 10 2011

Analytik Jena (Germany) launches its new atomic absorption spectrometer contrAA® 600. The device complements the contrAA® product family and optimizes the advantages of high resolution continuum source atomic absorption spectrometry (HR-CS AAS) specifically for the graphite furnace technique.

"With the development of the contrAA® 600 we have rounded out our contrAA® portfolio with an important product. The graphite furnace device closes the gap between the contrAA® 300 for flame and hydride technology and the contrAA® 700, which combines flame, hydride and graphite furnace technique", said Torsten Olschewski, head of the business unit Analytical Instrumentation. "In environmental and food analysis, for example, or in clinical chemistry the graphite furnace technique in combination with HR-CS AAS is the right choice, especially for the ultra trace analysis."

By using a special Xenon short arc lamp as continuous radiation source in combination with a high resolution Echelle spectrometer, the wavelength relevant for the atomic absorption becomes immediately available. Thanks to the combination of the two components the analysis graph and the total spectral environment can be recorded simultaneously. Additional benefits: The simultaneous background correction and significantly reduced detection limits increase the accuracy of the measured results. Using HR-CS AAS it is now also possible to analyse molecular bands and thus detect additional elements that cannot be analysed using standard AAS technology.

In combination with the direct solid analysis technique from Analytik Jena solid samples can be processed in the graphite furnace method without extensive sample preparation. This advantage saves much time and cost for users during their daily work. When using HydrEA technology - to detect hydride-forming elements - contrAA 600 achieves the best detection limits whilst simultaneously minimising matrix effects.


Digital Edition

PIN 25.4 Aug/Sept

September 2024

Analytical Instrumentation - Novel and Rapid LSC method for the analysis of biogenic carbon in fuels Measurement and Testing - Matrix evaluation on the Xplorer-V with Vectra autosampler accordi...

View all digital editions

Events

WasteTech

Sep 10 2024 Moscow, Russia

Thailand Lab 2024

Sep 11 2024 Bangkok, Thailand

Sensor China

Sep 11 2024 Shanghai, China

Oil & Gas Indonesia 2024

Sep 11 2024 Jakarta, Indonesia

Tanzania Energy Congress

Sep 11 2024 Dar es Salaam, Tanzania

View all events