• New High Resolution Continuum Source Atomic Absorption Spectrometer Launched

Analytical instrumentation

New High Resolution Continuum Source Atomic Absorption Spectrometer Launched

Analytik Jena (Germany) launches its new atomic absorption spectrometer contrAA® 600. The device complements the contrAA® product family and optimizes the advantages of high resolution continuum source atomic absorption spectrometry (HR-CS AAS) specifically for the graphite furnace technique.

"With the development of the contrAA® 600 we have rounded out our contrAA® portfolio with an important product. The graphite furnace device closes the gap between the contrAA® 300 for flame and hydride technology and the contrAA® 700, which combines flame, hydride and graphite furnace technique", said Torsten Olschewski, head of the business unit Analytical Instrumentation. "In environmental and food analysis, for example, or in clinical chemistry the graphite furnace technique in combination with HR-CS AAS is the right choice, especially for the ultra trace analysis."

By using a special Xenon short arc lamp as continuous radiation source in combination with a high resolution Echelle spectrometer, the wavelength relevant for the atomic absorption becomes immediately available. Thanks to the combination of the two components the analysis graph and the total spectral environment can be recorded simultaneously. Additional benefits: The simultaneous background correction and significantly reduced detection limits increase the accuracy of the measured results. Using HR-CS AAS it is now also possible to analyse molecular bands and thus detect additional elements that cannot be analysed using standard AAS technology.

In combination with the direct solid analysis technique from Analytik Jena solid samples can be processed in the graphite furnace method without extensive sample preparation. This advantage saves much time and cost for users during their daily work. When using HydrEA technology - to detect hydride-forming elements - contrAA 600 achieves the best detection limits whilst simultaneously minimising matrix effects.


Digital Edition

PIN 26.2 April/May 2025

May 2025

Articles - High-Temperature Rotational Viscometry: Automatizing Standards and Understanding Temperature Effects on Measurements - HPM High Load Lubricant Specifications - How Reliable is Your F...

View all digital editions

Events

ASTM - D02 Meeting

Jun 22 2025 Kansas, MI, USA

IMCS

Jun 22 2025 Freiburg Germany

AUTOMATICON

Jun 24 2025 Warsaw, Poland

Sensors Converge

Jun 24 2025 Santa Clara, CA, USA

Downstream 2025

Jun 25 2025 Houston, TX, USA

View all events