• Fast, Reliable Detection of O2, H2S or CO

Personal gas monitor

Fast, Reliable Detection of O2, H2S or CO

Draeger (Germany) is expanding its family of single gas detectors with the launch of the Draeger Pac 3500 and Draeger Pac 5500. Designed for personal protection and ideal for use in oil and gas, chemical, power generation, steel, water and other general industrial applications, these compact gas detectors measure the concentration of oxygen, carbon monoxide or hydrogen sulphide in the air. Both instruments use minimal battery power and, because they have low maintenance requirements, offer a low cost of ownership.

The Draeger Pac 3500 has a lifespan of approximately two years and the Draeger Pac 5500 has an indefinite lifespan with proper maintenance and servicing. Both units feature the same powerful Draeger detection technology.

The integrated Draeger XXS sensors offer an expected lifespan of five to eight years. The same is true of the oxygen sensor, which operates consumption-free and has been produced lead-free. The triple electrode technology on which it is based has been patented and prevents early sensor wear. The battery and filter of the Draeger Pac 3500 can be replaced while the sensor does not have to be changed over the complete instrument life. The battery, sensor and filter of the Draeger Pac 5500 can be easily replaced without the need for special tools.

The Draeger Pac 3500 and the Draeger Pac 5500 allow the gas to enter the sensor from several directions. This reduces the risk of an accidentally covered inlet preventing access to the sensor for measurement. The sensors detect the gases quickly and reliably. When used to detect hydrogen sulphide, the instrument indicates measurements with one decimal point and, as a result, is ideal for low warning thresholds and reduced limit values.

Featuring a short response time, both instruments are quick to generate visual, acoustic and vibrating alarms during a hazardous situation.

Used to test instrument function, the Draeger Bump Test Station operates without a power supply. This means that the mandatory daily tests can be carried out on-site and without undue delay to the work process – even when large numbers of instruments are involved. The optional test for each instrument takes eight to fifteen seconds, ensuring quick, easy testing. The userprogrammable bump test and calibration intervals mean that the detectors can be configured to stop automatically after an adjustable tolerance period if the user ignores the request for a bump test. The same applies to the (non-)observance of regular service and calibration intervals in the workshop.


Digital Edition

PIN 25.6 Buyers' Guide

January 2025

Buyers' Guide Directory - Product Listings by Category - Suppliers Listings (A-Z) Articles Analytical Instrumentation - ASTM D7042: The Quantum Leap in Viscosity Testing Technology -...

View all digital editions

Events

Trinidad and Tobago Energy Conference 2025

Feb 10 2025 Point Lisas, Trinidad

SAIPEC

Feb 11 2025 Lagos, Nigeria

Saudi Downstream

Feb 13 2025 Manama, Bahrain

EGYPES Egypt Energy Show

Feb 17 2025 Cairo, Egypt

IPTC 2025

Feb 18 2025 Kuala Lumpur, Malaysia

View all events