GC Columns Bring High Temperature Stability to Mid-Polarity Analyses

Aug 19 2009 Read 1175 Times

Phenomenex Inc., (USA) announces the expansion of its successful Zebron Inferno high-temperature GC column line, adding two new mid-polarity columns. The new ZB-XLB-HT and ZB-35HT are the first mid-polarity columns that can withstand temperatures up to 400˚ C, enabling analyses of compounds with high molecular weights and boiling points. The Zebron Inferno non-metal columns are stable at high temperatures due to proprietary coating and binding technologies, providing long lifetime, low bleed and low activity. They are ideal for analyses in environmental, food and beverage, pharmaceutical, toxicology and biofuels applications.

Standard fused-silica columns are not engineered to withstand temperatures above 380˚C and their polyimide coating begins to degrade, eventually becoming brittle and inflexible. The Phenomenex Inferno columns are specially designed for high-temperature analysis, with more rugged stationary phases and coating.

The ZB-XLB-HT Inferno column is stable up to 400˚C and provides unique selectivity for confirmational analyses. This MS-certified column offers low activity and good peak shape for acidic and basic samples. The ZB-XLB-HT proprietary phase is ideal for polychlorinated biphenyls (PCBs), pesticides, herbicides and many EPA methods. The ZB-35HT is a 35%-phenyl-65%-dimethylpolysiloxane intermediate-polarity column that is stable up to 400˚C, enabling high molecular weight analysis. It is particularly well suited for trace analysis with bleed-sensitive detectors. Applications include semi-volatile compounds, pesticides, drugs of abuse, pharmaceuticals, steroids and many EPA methods.

“Our successful Zebron columns were the first non-metal columns to provide stability at very high temperatures,” commented Ngoc Nguyen, brand manager for Phenomenex. “The increased column stability can be beneficial even for routine temperature ramps above 320 °C, which can cause some GC columns to become brittle and produce high bleed.”
 

Read comments0

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.


Digital Edition

Petro Industry News September 2018

September 2018

In This Edition Fuel for Thought - New Partnership for the US Distributio - Element opens new oil and gas laboratory in Singapore - Metrohm Acquires B&W Tek Analytical Instrumentation...

View all digital editions

Events

FiGas

Oct 25 2018 Lima, Peru

analytica China

Oct 31 2018 Shanghai, China

Mozambique Gas Summit

Oct 31 2018 Maputo, Mozambique

SETAC North America

Nov 04 2018 Sacramento CA, USA

View all events