• New Guided Wave Radar Level Transmitters for Safety Instrumented Systems

Flow Level Pressure

New Guided Wave Radar Level Transmitters for Safety Instrumented Systems

Sep 22 2009

Emerson Process Management (UK) announces availability of its Rosemount® 5300 Guided Wave Radar (GWR) level transmitters for SIL 2 safety instrumented systems. Following successful third-party evaluation,
the 5300 series now comes with the required Failure Modes, Effects and Diagnostic Analysis (FMEDA) report. As a result, companies in the oil & gas production, refining, petrochemical, chemical and power industries can benefit from the superior performance of Guided Wave Radar (GWR) technology while ensuring compliance with associated IEC industry standards.

The 5300 Series was evaluated, as per hardware assessment IEC 61508, by global organisation Exida. The resulting FMEDA report, with Safe Failure Fraction (SFF) over 90%, shows SIL 2 suitability. As per IEC
61508 & IEC 61511 the documentation provides safety instrumentation engineers with the required failure data and with proof test recommendations. With a five-year-plus proof test interval, the proof test can be co-ordinated with plant turnaround, minimising process interruption and reducing risk to personnel.

The Rosemount® 5300 series is a 2-wire GWR for challenging level and interface measurements on liquids, slurries and solids. It leverages the company’s 30 years of proven radar expertise and is designed to improve plant profitability through superior reliability, state-of-the-art safety features, effortless handling and unlimited connectivity.

The Rosemount® 5300 has an enhanced capability to handle disturbing factors, longer measuring range, and lower dielectrics, even with a single probe. Its robust design prevents leakage and performs reliably, especially under extreme process conditions. Heavy-duty probes are available to meet the extreme temperatures and pressure challenges with multiple layer of protection and advanced echo logics for reliable overfill detection.

The 5300 series’ 2-wire technology enables fast and inexpensive installation. With user-friendly graphical interfaces and wizards, measure-and-learn functionality, suggestions for application-specific configuration and PlantWeb® digital architecture functionality, the transmitter integrates easily into new or existing control systems. This, in addition to maintenance-free operation and advanced diagnostics, results in a quicker return on investment with overall improved uptime and enhanced safety.

Rosemount transmitters are components of Emerson’s smart SIS safety management solution, an extension of the company’s PlantWeb® digital plant architecture. Emerson’s smart SIS provides an integrated approach to complete safety loops — from sensor to logic solver to final control element. The smart SIS solution enables process manufacturers to implement safer facilities, improve availability, lower life-cycle costs, and simplify regulatory compliance. The smart SIS system components include Rosemount® and Micro Motion® certified and proven-in-use devices, the DeltaV™ SIS system, the Fisher certified valves or SIL-PAC final control solution
with FIELDVUE DVC6000 SIS, and the AMS® Suite: Intelligent Device Manager.


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

Saudi Plastics and Petrochem

May 06 2024 Riyadh, Saudi Arabia

View all events