Rigaku Corporation (USA) recently announced the publication of a new application report describing the analysis of low concentration sulphur in automotive fuels using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry. Rigaku Application Note #XRF 5035 adheres to the American Society for Testing and Materials method ASTM D2622-10 (“Standard Test Method for Sulphur in Petroleum Products by Wavelength Dispersive X-ray Fluorescence Spectrometry”) and highlights the capabilities of the Rigaku Mini-Z Sulphur analyser.

Recent developments in ultra-low sulphur diesel (ULSD) fuel have improved fuel efficiency and created cleaner emissions. The allowable limit of sulphur in fuel oils has been reduced by as much as 15 ppm in many countries, with the likelihood of further restrictions still to come.

For compliance verification, X-ray fluorescence (XRF) spectrometry is the preferred analysis tool for use at distribution terminals, as well as at mobile or stationary testing laboratories. Application Note #XRF 5035 details sample preparation, method calibration and repeatability. For the analysis described in the report, 4 ml of each sample was poured into a special liquid cell with a 2.5 μm Mylar analysis film. “Number 2 diesel fuel” standards and isooctane-based standards were used for calibration for diesel fuel and gasoline respectively.

Measurements were carried out using the Mini-Z Sulphur analyser, a benchtop single fixed-channel WDXRF spectrometer designed to minimise installation requirements such as cooling water, power supply and floor space. It has a built-in control panel designed for easy operation. The Mini-Z Sulphur analyser is equipped with an air-cooled 40 W Cr-target X-ray tube. The RX-9 analysing crystal is optimised for sulphur analysis.

The results show that low concentration sulphur in petroleum-based fuel can be routinely analysed with high precision using the Mini-Z Sulphur analyser, meeting the requirement of the current ASTM D2622-10 method.

A copy of this application report may be requested on Rigaku’s official website at: http://j.mp/ZGIyz7


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

Saudi Plastics and Petrochem

May 06 2024 Riyadh, Saudi Arabia

View all events