• PRESTO case studies available online

Analytical Instrumentation

PRESTO case studies available online

May 18 2016

JULABO’s PRESTO represent an entirely generation of highly dynamic temperature control systems. The PRESTO systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations.

The PRESTO from JULABO represent the state-of-the-art for modern laboratories. These instruments cover a working temperature range of -92°C to +250°C with high cooling and heating capacity. Maximum heating capacity can also be adapted to fluctuations in the mains power supply. Highly efficient components give these instruments the ability to compensate for exothermic and endothermic reactions with extraordinary speed. The PRESTO units are extremely robust and work reliably even if the ambient temperature climbs as high as +40°C. The integrated cooling machine and an internal, cooled expansion vessel absorb volume changes in the heat exchanger.

PRESTO systems are ideal for reactor tempering
PRESTO systems can be connected to different reactors using the available JULABO tubing. For example the PRESTO A80. With a heating capacity of 1.8 kW the PRESTO A80 is able to heat up this 20 liter reactor from 0°C to +50°C in under 90 minutes without any overshoot.

PRESTO are able to cover different applications
Whether your application is low temperatures or the fast control and compensation of exothermic and endothermic reactions: PRESTO® can do it. With a cooling capacity of 1.2 kW (at +20°C) the PRESTO A40 is able to cool down a 20 l reactor from 0°C to -20°C within one hour 15 minutes.

Low temperatures – no problem for PRESTO
What's the lowest temperature that can be reached? That's what we test with our PRESTO devices and reactors from different suppliers. For example the PRESTO A45 can achieve the lowest temperature of -36°C even in a large 30 l reactor.

PRESTO highly dynamic temperature control systems are available online and case studies with PRESTO systems available click here.
 


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

UzChemPlast Expo

Apr 03 2024 Tashkent, Uzbekistan

ATYRAU Oil & Gas Kazakhstan

Apr 03 2024 Atyrau, Kazakhstan

analytica 2024

Apr 09 2024 Munich, Germany

ChemBio Finland 2024

Apr 10 2024 Helsinki, Finland

View all events