PEFTEC - Enhanced Molecular Weight Information in GC/MS by Cold EI

Analytical instrumentation

PEFTEC - Enhanced Molecular Weight Information in GC/MS by Cold EI

11 May, 2016

Published over 10 years ago. See the latest and most current information on Analytical instrumentation.

Mr Timon Huybrighs, Mr Christophe Clarysse and Dr Adam Patkin
1 min read
Download

Electron Ionization Gas Chromatography / Mass Spectrometry (EI GC/MS) is a powerful and information-rich technique for qualitative characterization and quantitative analysis of the compounds in a mixture. One of its most valuable functions is to provide the molecular weight of a compound. However, many compounds do not have a stable molecular ion under EI conditions and it is small or absent in the spectrum.

Cold Electron Ionization GC/MS (Cold EI GC/MS) can enhance the molecular ion abundance of most compounds while retaining the EI fragmentation pattern for spectral library searching.

The enhanced molecular ion intensity is achieved by supersonic expansion of the GC effluent into a molecular beam, where the analyte molecules are vibrationally and rotationally cooled adiabatically to ~10 - 30 K. When this vibrationally cold molecule is ionized by a 70 eV electron the final thermal energy is much lower than in EI, which ionizes a molecule at GC transferline temperature of several hundred °C. The reduced Cold EI internal energy produces much less fragmentation of the molecular ion. The ion source used in this work is of axial "fly-through" design, eliminating molecule and ion collisional scattering with ion source walls which could lead to additional fragmentation. This is demonstrated for compounds such as squalane, which shows a large molecular ion with Cold EI, but <1% by conventional EI.

When used in a novel q-TOF configuration the enhanced molecular ion increases sensitivity, selectivity, and information content.

Latest White Papers

PIN 27.2 Apr/May 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
Severe asthma study discovers hidden clusters of long-term health conditions
Explore more Arrow
Envirotech Online
EU ETS benchmark update puts industrial emissions data under sharper scrutiny
Explore more Arrow
Pollution Solutions Online
DNV introduces new framework for measuring onboard carbon capture performance
Explore more Arrow
Chromatography Today
Non-invasive flowmeters for real-time monitoring
Explore more Arrow