• Panel Mount Free Chlorine Analyser Simplifies Monitoring, Reduces Maintenance, Lowers Cost 

Water/Wastewater

Panel Mount Free Chlorine Analyser Simplifies Monitoring, Reduces Maintenance, Lowers Cost 

Sep 09 2015

Municipal and industrial process engineers alike will find the new plug-n-play FC80 Panel Mount Free Chlorine Analyzer from USA-based Electro-Chemical Devices (ECD) simplifies water monitoring and treatment processes while installing easily and requiring less maintenance to lower cost-of-ownership.

The highly reliable FC80 Analyzer monitors free chlorine in drinking water, rinse water, cooling water or other fresh water samples from 0.05 – 20 ppm chlorine as the standard range or 0.01 - 5.00 ppm with the low range sensor. The FC80 is compliant with EPA method 334.0 for measuring drinking water.

The plug-n-play FC80 Free Chlorine Analyzer installs quickly right out of the box. The FC80’s advanced panel mount design includes built-in flow control, which eliminates the need for complicated pressure regulators and rotometers. Built-in automatic pH compensation also eliminates the need for expensive reagents to reduce maintenance and life-cycle costs.

The FC80’s panel mount design incorporates a constant head flow control device, a pH sensor, a chlorine sensor and ECD’s T80 analyser/transmitter conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use. Calibration is accomplished by DPD comparison.

Free chlorine exists in solution as a pH dependent ratio of hypochlorous acid (~100% at pH 5) and hypochlorite ion (~100% at pH 10). The ECD T80 free chlorine sensor measures only the hypochlorous acid component of the free chlorine and the analyzer calculates the balance using either the measured pH or a user defined fixed value. The use of the pH sensor provides accurate compensation for samples between pH 6 and pH 9 eliminating the need for expensive sample conditioning systems to control the pH of the solution.

The FC80 Analyzer is available with either 110-240 VAC or 24 VDC power. Parameters can be graphically displayed with user defined line, bar or gauge style graphs. The standard configuration has two 4-20 mA outputs, three alarm relays and a MODBUS RTU.

The user friendly FC80 is available with an Auto Clean option that includes a solenoid actuated spray cleaner using either 30 psi process water or air. An easily adjusted timer controls the period and duration of the cleaning cycle.


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events