• pH  Measurement and Control of Oil Refinery Desalter Wash and Brine Waters

Water/Wastewater

pH  Measurement and Control of Oil Refinery Desalter Wash and Brine Waters

Jan 12 2015

Crude Oil contains unwanted contaminants that must be removed before refining, such as salt and other contaminants: KCl potassium chloride , NaCl, MgCl, CaCl, sand, drilling mud and paraffin waxes.

These contaminants are removed by electrolysis with the 5-9% addition of water, which require pH installations for the monitoring of desalter wash waters and brine effluent waters.

These can both prove challenging. The wash waters have a pH 5.5 - pH 7.00 contaminated with Ammonia and Phenols Temperatures can > 100 C, and the brine effluent waters contain sulphides, heavy metals, and oil - this cocktail is often very abrasive. Electrode fouling and poisoning is a risk.

The Refex (USA) / pH combined and separate electrodes have the new and patented NON-POROUS ionically conductive interface that separates the wash and brine effluent waters from the electrode's Ag/AgCl reference half cell and KCl electrolyte.  This is 100% resistant to H2S/Ammonia poisoning and electrode fouling.

The recommended Refex EC-3/4-2001-Pt1000-LE ( 1m, 3m,5m,10m cable options)  all in one combined electrode with 3/4" NPT process fitting gives fast responses to pH change, and combine a long-life with chemical savings (No over-shoot beyond pH High/Low set points), resulting in big savings for your operation. 


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events