Identifying and quantifying trace hydrocarbon impurities in 1,3-butadiene is critical in producing high quality synthetic rubber products. Standard analytical methods employ alumina PLOT columns which yield good resolution for low molecular weight compounds, but suffer from irreproducibility and poor sensitivity for more polar hydrocarbon impurities, like propadiene, acetylene, and methyl acetylene. New Rt®-Alumina BOND/MAPD PLOT columns feature a unique deactivation that improves response level and predictability for diene and acetylene hydrocarbons. In addition, these columns have a higher maximum temperature (up to 250°C) which extends the application range. Here, we demonstrate the utility of these columns for analyzing trace polar hydrocarbon impurities in 1,3-butadiene.

1,3-butadiene is typically isolated from products of the naphtha steam cracking process.
Prior to purification, 1,3-butadiene can be contaminated with significant amounts of isobutylene as well as other C4 isomers. In addition to removing these C4 isomeric contaminants during purification, it is also important that 1,3-butadiene be free of propadiene and methyl acetylene, which can interfere with catalytic polymerization. Alumina PLOT columns are the most commonly used GC column for this application; however, the determination of polar hydrocarbon impurities at trace levels can be quite challenging and is highly dependent on the deactivation of the alumina surface. Restek has recently developed a new line of alumina columns with a unique, high-performance deactivation. These columns—the Rt®-Alumina BOND/MAPD (fused silica) and MXT®-Alumina BOND/MAPD (metal) columns—are ideal for the analysis of polar hydrocarbons such as acetylene, methyl acetylene, and propadiene, and also perform well for generic light hydrocarbon analysis.

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

PIN 24.5 Oct/Nov 2023

November 2023

In This Edition Measurement and Testing - Comparison between NIR/FT-IR and 3rd Generation OP-NMR Technology - Refinery Boiler Replacement Project’s Air & Fuel Gas Measurement Challenges So...

View all digital editions

Events

ASTM - DO2 Meeting

Dec 03 2023 New Orleans, LA, USA

Biogas Convention & Trade Fair 2023

Dec 12 2023 Nuremberg, Germany

Turkey & Black Sea Oil and Gas

Dec 13 2023 Istanbul, Turkey

IGC 2023

Dec 14 2023 Roorkee, India

Americas Energy Summit and Exhibition

Jan 16 2024 New Orleans, LA, USA

View all events