• Dedicated solution for online monitoring of ammonia in wastewater streams

Laboratory Products

Dedicated solution for online monitoring of ammonia in wastewater streams

Feb 07 2018

Metrohm Process Analytics offers a dedicated solution for hassle-free online monitoring of ammonia in wastewater streams. This turn-key solution uses photometric determination and is performed on the ICON Analyser, a dedicated online photometer for water and wastewater analysis.

The importance of nutrient removal in the form of nitrogen in industrial and municipal wastewater has increased significantly over the past decade to minimise water pollution and avoid eutrophication of water bodies. Nitrogen present in wastewater as mostly organic nitrogen, ammonium/ammonia and nitrate must be treated to meet stringent effluent requirements imposed by legislation. Biological nutrient removal processes (BNR) in place at modern wastewater treatment plants employ nitrification and denitrification processes to convert ammonium into harmless N2 gas, which is then released into the atmosphere.

Online monitoring of the nitrogen compounds in waste effluent guarantees high nutrient treatment efficiency and low operating and energy costs. For example, an increase in ammonia and nitrite levels in the effluent indicate an insufficient aeration step or that a change in toxicity or pH is disturbing the nitrifier (bacteria) population. Costs incurred from a plant shutdown due to insufficient nutrient removal, including replacement of the bacteria, can be extremely high. Metrohm Process Analytics offers robust single-method process analysers which come fully configured for analyses such as ammonia and nitrite – just Plug and Analyse.

The fully-automated photometric ammonia analysis is based on the Berthelot method. After addition of a stabilised hypochlorite solution, the ammonia reacts quantitatively to monochloramine. The formed monochloramine creates a quinone monoimine when nitroprusside is added to the cuvette. This quinone monoimine reacts finally with a thymol molecule to the respective indophenol dye, which in an alkaline medium occurs in the blue basic form and is measured at 660 nm in a thermostated cuvette for added stability.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

View all events