The fastest and most efficient way to upgrade a magnetic level indicator
(MLI) is to clamp a Jupiter 200 magnetostrictive level transmitter from Magnetrol (Belgium) onto its by-pass cage. The installation can
be performed under process conditions and without any modification of
the installed equipment.
Magnetrol`s Jupiter 200 uses the electro-magnetic field of the float inside the by-pass cage of the MLI to determine the liquid level.
The Jupiter launches a high frequency signal over its probe (maximum length 5,7m; longer at request).
The magnetostrictive wire twists at the position of the float. This mechanical motion is in fact an acoustic signal that will be picked up by the piezo crystal inside the transmitters` head. The measurement
of the transit time between sending and receiving the signal results
in a very accurate level measurement (± 0,4mm). Since the signal has not
lost any amplitude, it is capable of tracking a second float position (liquid interface) with the same accuracy.
When needed, the Jupiter`s sensitivity and float polarity can be adjusted to the used float type via its menu. To eliminate all risks,
ask Magnetrol to perform a quick and easy test procedure.
HART®/AMS or FOUNDATION fieldbus™ protocol enables the user to
remotely configure the unit, monitor the measurement, identify malfunctions and realize effective troubleshooting.
The unit retains a history of events since its last reset. PACTware-FDT
technology and device specific DTM`s simplifies this even more over your
PC/laptop. The graphical display of the waveform and trending curves
contain valuable troubleshooting information.
Externally mounted, the Jupiter is not affected by process pressure. The
device can handle process temperatures ranging from -196°C up to +455°C. With a SFF of 90,70%, the Jupiter is suitable for use on SIL 2
loops (as 1oo1).

Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events