Open Path Gas Detector Offers Failsafe Detection of Hydrocarbons

Sep 12 2008

Featuring the latest infrared technology, Draeger`s (Germany) Polytron Pulsar Open Path Gas Detector is able to detect hydrocarbon leaks within a line of sight of up to 200m. Designed to provide failsafe detection of a wide range of hydrocarbons, this robust unit has built-in directional guidance and can be both aligned and commissioned without the need for special training.
Explosion proof and ideal for the detection of the alkane series, from methane to hexane, as well as propylene, methanol, ethanol and ethylene, the Polytron Pulsar is easy to use and can be commissioned
by just one person. The integral calibration requires no manual adjustment or standard test gas and the alignment and signal strength parameters can be logged and used to determine optimum operating conditions.
Carrying a Safety Integrity Level rating of 2 (SIL 2) and offering a response time of less than two seconds, the Polytron Pulsar is designed to ensure that all faults are detected, thereby providing failsafe protection.
A continuous signal between the receiver and transmitter allows the system to adapt to difficult environmental conditions, and high power xenon lamps, combined with a sophisticated algorithm which varies their intensity and frequency, makes the unit immune to solar radiation, stack flares, arc-welding and resonance effects from rotating machinery. Impervious to the effects of fog, mist and snow across the beam, it also features heated optics to eliminate snow and
icing and prevent condensation.
The internal data logger maintains a detailed record of the previous 7 days of operation, and consolidates records for the previous 32 weeks.
Containing essential information, these records can include actual readings, events such as beam block and gas alarms, warning flags, signal strength, alignment, supply voltage and internal temperature.
Digital communications between the field and the safe area can also be provided, without the need for extra cable cores, by the addition of HART. Enabling a complete installation to be monitored from a single
workstation, a HART configured system provides real time information on the status of an individual detector as well as configuration and historical data of each device. Useful when planning maintenance, HART can also provide substantial cost savings, particularly where
detectors are located in hard to reach areas.
In addition, gas calibrations and the signal span can be accessed and changed remotely with an AI500 digital interface. For larger installations, up to 32 AI500 devices can be connected via an RS485
interface to allow up to 128 Polytron Pulsar units to be monitored.
Meeting ATEX, IECEx UL, CSA and GOST approvals, the Polytron Pulsar can be supplied with a variety of operating distances from 4 to 60m, 30 to 120m or 100 to 200m and is designed for use in temperatures ranging
from –40 to +60°C.

Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

Saudi Plastics and Petrochem

May 06 2024 Riyadh, Saudi Arabia

View all events