• The new Point Open Path for superior Hydrocarbon detection

Measurement and Testing

The new Point Open Path for superior Hydrocarbon detection

May 30 2018

When measurement reliability and response time become critical factors in combustible gas detection, the new Point Open Path IR sensor from N.E.T. is the answer. Specifically developed to keep measurements immune from ambient humidity changes and T90 below 7 seconds, the POP-S-IR significantly improve traditional performances of Infrared sensor to detect Methane, Propane and other Hydrocarbons in LEL range.

The sensor uses an infrared energy source and two pyroelectric detectors, each sensitive to different ranges of wavelengths in the spectrum’s infrared portion. The Active detector is sensitive in the range of absorption of the target gas, while the Reference detector is not. The IR source is directed through a glass window into an open gas chamber. The light is reflected by a mirror at the end of the chamber back into the main enclosure and into the pyroelectric detectors. The presence of target gas in the measurement chamber reduces the intensity reaching the Active detector but not the one reaching the Reference detector. The ratio of the two signals is computed in a combustible gas concentration by the sensor microprocessor through N.E.T.’s proprietary algorithm.

Infrared technology dependability eliminates the need for frequent calibrations (the Long Term Drift is ±3% of FS range/year) and the sensor life is not impacted by exposure to gas and other contaminants, resulting in a dramatic reduction of Total Cost of Ownership.

The unit is certified like no other sensor on the market, with ATEX, IECEx and SIL approvals.

The long optical path improves detection performances, with an astounding accuracy of ±1% of FS range for readings below 25% of the nominal range and de facto immunity from ambient humidity effects.

The new Point Open Path IR sensor from N.E.T. can be easily integrated in any gas detector:

• The unit is a full conformity ATEX and IECEx explosion proof IR detector head for surface applications.

SIL2 rated, for certified dependability (fail-safe detection)

• Front thread (¾”, 1” or M20) to be easily mounted on a standard gas detector housing.

• Standard analogue (voltage/current) or customized output.

• Digital output with Modbus and UART P2P protocol.

• Supplied within a compact, weatherproof enclosure with rain cover. Optional dust and hydrophobic filters are available.


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

Saudi Plastics and Petrochem

May 06 2024 Riyadh, Saudi Arabia

View all events