New SPE Cartridge for Residue Analysis in Spices, Teas, and Other Dry Commodities

Jul 07 2017 Comments 0

Free to read

Articles are free to download. Please login to read this article or create an account.

Unlock

The complexity of dried sample matrices, such as teas and spices, frequently poses a challenge to food chemists when analyzing for residues. These extracts, containing residual oils and pigments, can contaminate chromatographic systems and cause both instrument fouling as well as inaccurate or irreproducible results. 

While the well-known and widely used QuEChERS cleanup approach is “Quick, Easy, Cheap, Effective, Rugged, and Safe,” the use of bulk salts and adsorbents, along with shaking and centrifugation, often does not provide sufficient capacity/efficiency to remove the concentrated matrix interferences associated with these dry commodities. 

Alternatively, solid phase extraction (SPE) cartridges, having a higher capacity/efficiency for matrix removal, are often used to remove these problematic interferences. Typically, along with other adsorbents, these SPE cartridges contain graphitized carbon black (GCB) for retention and removal of pigments from the extract. While the planar, graphitic surface of traditional GCB allows for excellent removal of chlorophyll and other pigments, it unfortunately also retains planar aromatic compounds such as planar pesticides. Typically toluene is often needed to recover the planar analytes. Consequently, toluene introduces additional problems later in the work up and analysis.  

The multi-bed Supelclean™ Ultra 2400 SPE cartridges are designed for the cleanup of extracts from dry/difficult samples prior to pesticide residue analysis, typically performed by GC/MSMS and LC/MS/MS. These cartridges contain primary-secondary amine (PSA), C18, zirconia-coated silica (Z-Sep), and a specialized, spherical carbon.  These adsorbents provide an optimal balance between analyte recovery and interference removal without the use of toluene.  

The top bed of the Ultra 2400 cartridge contains a mixture of PSA/C18 and graphitized, spherical carbon. The PSA removes acidic interferences, the C18 retains some hydrophobic lipid interferences, and the carbon removes unwanted pigments. The specialized carbon adsorbent used in this cartridge was engineered to remove sufficient pigmentation while also allowing for acceptable recoveries of compounds with planar structures. The bottom bed of the cartridge contains Z-Sep, which removes remaining oily residues and provides additional pigment removal.  As seen with the analysis of pesticides in turmeric, the cartridge can be used for cleanup of acetonitrile extracts to be analyzed by either GC or HPLC. To learn more and try a sample, visit sigma-aldrich.com/supelcleanultra.

 


Digital Edition

Petro Industry News October/ November 2017

October 2017

Fuel for Thought - Restek Wins Company of the Year ASTM News - New Standard Helps Meet Need for Hydrocarbon Impurity Testing PEFTEC Preview - Excitement Builds for PEFTEC 2017 - Det...

View all digital editions

Events

INCHEM TOKYO 2017

Nov 20 2017 Tokyo, Japan

Romania Oil & Gas

Nov 21 2017 Bucharest, Romanis

Oil. Gas. Chemistry

Nov 22 2017 Krasnoyarsk, Russia

PEFTEC 2017

Nov 29 2017 Antwerp, Belgium

Tank Storage Germany

Nov 29 2017 Hamburg, Germany

View all events