pH  Measurement and Control of Oil Refinery Desalter Wash and Brine Waters

Jan 07 2015

Crude Oil contains unwanted contaminants that must be removed before refining, such as salt and other contaminants: KCl potassium chloride , NaCl, MgCl, CaCl, sand, drilling mud and paraffin waxes.

These contaminants are removed by electrolysis with the 5-9% addition of water, which require pH installations for the monitoring of desalter wash waters and brine effluent waters.

These can both prove challenging. The wash waters have a pH 5.5 - pH 7.00 contaminated with Ammonia and Phenols Temperatures can > 100 C, and the brine effluent waters contain sulphides, heavy metals, and oil - this cocktail is often very abrasive. Electrode fouling and poisoning is a risk.

The Refex (USA) / pH combined and separate electrodes have the new and patented NON-POROUS ionically conductive interface that separates the wash and brine effluent waters from the electrode's Ag/AgCl reference half cell and KCl electrolyte.  This is 100% resistant to H2S/Ammonia poisoning and electrode fouling.

The recommended Refex EC-3/4-2001-Pt1000-LE ( 1m, 3m,5m,10m cable options)  all in one combined electrode with 3/4" NPT process fitting gives fast responses to pH change, and combine a long-life with chemical savings (No over-shoot beyond pH High/Low set points), resulting in big savings for your operation. 


Digital Edition

PIN 25.2 Apr/May

May 2024

Safety - Carbon monoxide toxic and flammable gas detection Analytical Instrumentation - Density: A fundamental parameter at critical stages within the petroleum sector - Advancements and...

View all digital editions

Events

IOSC 2024

May 13 2024 New Orleans, LA, USA

OGU 2024

May 14 2024 Tashkent, Uzbekistan

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

REGATEC 2024

May 15 2024 Lund, Sweden

CO2 Capture, Storage & Reuse

May 15 2024 Copenhagen, Denmark

View all events