• The EE300Ex Humidity & Temperature Transmitter Conforms to International Standards for Intrinsically Safe Applications
    The EE300Ex humidity & temperature transmitter from E+E Elektronik conforms to international standards for intrinsically safe applications.
  • A variety of different models of the EE300Ex offer a high degree of flexibility in application.

Measurement and Testing

The EE300Ex Humidity & Temperature Transmitter Conforms to International Standards for Intrinsically Safe Applications

Jan 21 2015

The intrinsically safe EE300Ex humidity & temperature transmitter from E+E Elektronik conforms to the European ATEX Directive and now also to the international IECEx and the FM classification specifically relevant to the USA and Canada. This makes the device suitable for worldwide usage in explosion hazard areas.

The EE300Ex was developed for use in explosion hazard environments and can be mounted directly in both gas and dust hazard areas of zone 0 / Div1. Precise humidity and temperature measurements from 0…100 %rel. hum. and -40…180 °C (-40...356 °F) are also possible in applications under pressure up to 300 bar (4351 psi). Just as with humidity measurement in air, the EE300Ex can also be used for moisture measurement in oils. 

Various models of the EE300Ex offer a high degree of flexibility. As a compact variant – with or without display – the transmitter can be mounted directly in the hazard area. With a remote probe, temperature classifications up to T6 can also be achieved. Depending on requirements, an EE300Ex model for combined humidity and temperature measurement or for temperature measurement only is available.

The two-part stainless steel housing (separate connection area and measurement unit) simplifies installation of the transmitter considerably. It also permits the rapid replacement of the measurement unit – such as for calibration – without time-consuming re-cabling.

The measured values are issued on two analogue outputs with 4…20mA. The power can be supplied via any intrinsically safe power supply device. In addition to the measured values for humidity and temperature, dew point, frost point, absolute humidity, mixing ratio and other calculated values can also be issued.

The configuration software permits customised configuration of the transmitter outside the hazardous area and permits, flexible, simple and rapid adaptation of the analogue ­outputs for the relevant application.

About E+E Elektronik


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

Hannover Messe

Apr 22 2024 Hannover, Germany

FORUMESURE

Apr 22 2024 Marrakech, Morroco

Oman Petroleum & Energy Show

Apr 22 2024 Muscat, Oman

World Energy Congress

Apr 22 2024 Rotterdam, Netherlands

Asia Pacific Energy Summit

Apr 23 2024 Singapore

View all events